Overview

The TCO Series Oil Temperature Control Unit is a high-performance process temperature control solution designed for extrusion, blow molding, injection molding, and other industrial manufacturing applications requiring elevated operating temperatures. Utilizing heat transfer fluid, the TCO Series delivers accurate and dependable temperature control up to 550°F (288°C) to support consistent processing conditions and product quality.

Engineered for demanding applications, the TCO Series offers multiple flow, pressure, and heater configurations to match a wide range of process requirements. Its robust design, flexible customization options, and ability to maintain critical temperatures within 1°F (0.55°C) make it an ideal solution for processors seeking precise high-temperature control and reliable long-term performance.

Specifications

ModelPump
HP (kW)
Flow
GPM (LPM)
Pressure
PSIG (bar)
FLA by Heater Selection 460vDimensions in Inches (cm)Shipping Wt.
Lbs (kg)
6 kW12 kW18 kW24 kWHeightWidthDepth
TCO1.0 (0.75)18 (68)30 (2.0)916243146.9 (119)18.3 (46)43.9 (112)600 (272)
TCO1.5 (1.12)18 (68)50 (3.4)1017253246.9 (119)18.3 (46)43.9 (112)600 (272)
TCO2.0 (1.49)24 (91)30/50 (2/3.4)1118263346.9 (119)18.3 (46)43.9 (112)600 (272)
2TCO1.0 (0.75)18 (68)30 (2.0)1832486246.9 (119)36.5 (93)43.9 (112)1200 (546)
2TCO1.5 (1.12)18 (68)50 (3.4)2034506446.9 (119)36.5 (93)43.9 (112)1200 (546)
2TCO2.0 (1.49)24 (91)30/50 (2/3.4)2236526646.9 (119)36.5 (93)43.9 (112)1200 (546)

Features

Standard FeaturesOptional Features
Temperature range from 100°F to 550°F* (38°C to 288°C)12 kW, 18 kW, or 24 kW heater
Eurotherm 3216 micro-processor controller with “To-Process” and “Setpoint” LED readoutsAvailable optional voltages: 575/3/60, 380/3/50, 415/3/50, 208/3/60, 230/3/60
Positive displacement pump capable of reversing to evacuate the processAdvanced Controller with more robust informational display
Easily removable panels for quick access to internal componentsRemote Controls enclosure to allow operators full access to unit control from a desired location
Pressure activated bypass valveHour meter to monitor pump run time
Configurable auto vent sequence to automatically vent air from the system at start-upClosed loop heat exchanger to cool heat transfer fluid
Independent high temperature safety thermostat to protect from heater overloadGeneral fault visual alarm to alert operators of unit issues
Motor branch circuit overcurrent protection with phase loss and overload trip detectionMulti-zone capable in various design styles that include common wiring and/or piping
Y-strainer on the From Process lineProtective Lexan® cover for additional protection in harsh environments
Forward-facing liquid-filled “To Process” pressure gauge
Pressure switch for low pump pressure shutdown
Audible alarm
Low level alarm for reservoir
Drain valve for heat transfer fluid removal and change
1 year parts and labor warranty at the factory
3 year controller warranty