TrueTemp TC120 Series Water TCU
Custom Pricing




The AEC TrueTemp TC120 Series Water Temperature Control Units provide highly accurate control for production applications requiring a continuous supply of temperature-controlled water.
Innovative design promotes turbulent water flow to maximize heat transfer performance. High flow pumps with 32°F to 250°F (0°C to 121°C) setpoint operating range. The cast-and-flange design reduces connection points by 40% while including high-efficiency pumps that offer higher flow rates at lower pressures. These highly efficient products maintain temperatures to within 1°F of setpoint, allowing for tighter temperature control and improved throughput.
| Pump HP (kW) | Flow GPM (LPM) | Pressure PSIG (bar) |
|---|---|---|
| 0.75 (0.56) | 30 (114) | 25 (1.72) |
| 1.0 (0.75) | 35 (133) | 30 (2.07) |
| 2.0 (1.5) | 50 (189) | 30 (2.07) |
| 3.0 (2.24) | 60 (227) | 40 (2.76) |
| 5.0 (3.76) | 75 (284) | 54 (3.72) |
| 7.5 (5.6) | 90 (341) | 63 (4.34) |
| Dimension | Measurement |
|---|---|
| Height | 28.8" (73 cm) |
| Width | 14.0" (35.6 cm) |
| Depth | 28" (71.1 cm) |
| Standard Features | Optional Features |
|---|---|
| Compact design with easy-access side panels for rapid maintenance | Advanced M2C Controller |
| Programmable auto vent sequence to automatically vent air from the system at start-up | 12 kW, 18 kW, or 24 kW heater options |
| Independent high temperature safety thermostat to protect from heater overload | Maintained START/STOP switch |
| Motor branch circuit overcurrent/overload protection | General fault audio/visual alarm to alert operators of unit issues |
| Integrated cooling solenoid valves for efficient unit cooling | Pressure regulator/relief valve for water supply |
| Forward-facing liquid-filled To and From Process pressure gauges | Auto system water purge |
| 9kW dual circuit immersion heater with IEC contactors | Y-strainer to protect unit from high particulate fluid |
| Operator friendly PID temperature controller with Process and Setpoint LED readouts and straightforward unit performance data | 300°F (149°C) operations, includes silicon carbide/silicon carbide seal (requires 55 psig (379 kPa/3.8 bar) water supply pressure) |
| Graphic control panel with indicator and warning status lights | Non-fused lockable rotary through door disconnect |
| Adjustable low supply water pressure switch; 16 psig (1.1 bar) | |
| 150 psig (10.3 bars) pressure relief valve | |
| SICB/carbon pump seal to maximize pump life | |
| 0.75" water supply connection, 1.5" process connections; valve size matches drain size | |
| Quick cool for rapid unit cooling | |
| 1 year warranty on parts and labor at the factory | |